If you want to make money with a warm water pressure washer (sometimes referred to as a steam cleaner) in the contract cleaning sector, you are definitely going to need auxiliary power. Perhaps you ought to run a waste rinse water reclaim device, or even you just need some powerful lights to work at night. Either way you do need electricity to power up the burner to heat this type of water. Not long ago, I was discussing these problems with a mobile fleet cleaning operator, and he asked this most excellent question;

\”I\’m considering electric motors on that pumps and running them collected from one of larger generator. That way That i have on board electric for whatever I need, plus the ability to own flood lights as well for night work. Generator exhaust systems are also designed quieter – your thoughts? \”

[youtube]http://www.youtube.com/watch?v=T8TfYXJE-uY[/youtube]

Yes, we have done the following before, and if you become a really quiet big Honda generator, it\’s really nice to cooperate with no noise. Onan, additionally makes a quiet diesel-engined generator, actually have one of these on my motor home 7. 5, it\’s a fantastic generator, just awesome in every regard and you can hardly tell when it\’s functioning. I like the Hondas better because they\’re less maintenance.

If that you wanted to go eco-friendly you could use a large generator, and that way you would always have electricity for lights, functioning the pumps, and your burner. And if you had LP to fire that burner, you would be both clean and restful. You should also know that most of the skid pressure washer items do have two 110 outlet plugs about them, but, we always upgraded our units to have 17. 5 amps.

This way they could run some sort of 5 hp craftsman vacuum cleaner shop vac, lights (two) 1 million candle watts on tripods, along with the burner too, although which maxed it out, to make sure you couldn\’t start the vacuum motor since it would spike and trip the circuit breaker. Believe me you will get into situations depending on which type of cleaning you do, where you need everything that and more, and if you don\’t have it at the time, you\’ll be cursing yourself for not putting in the capital investment to do the trick right – you\’ll probably wish you had more.

Nevertheless, if you do upgrade to 17. 5 amps and greater, you will need a larger motor on your skid unit. I believe most of the units we were building had 18 to 22 hp so that we can do everything that for industrial work.

Which means that, you can get by without a generator and still have amperage for reclaim unit vacuum pumps, lights, vacuum cleaners, etc. – even power tools practical too. I suppose, the reality is you want to make sure that you can do all the work that you set out to do, and you want to be able to take all the jobs that pay the most money.

If you\’re just going to do busy work and cleaning auto dealership car a lot, you may as well just get a small cold water unit, rent a couple C and W de-I tanks, or put in RO system that your house, fill up 500 gallon tanks, take the GPM down to 2. 2 to 3. 5 gallons for each minute and 1500 – 2200 PSI and go to town. Please consider that.

I am offering a premium range of diesel generators that are widely are used in places without connection to the power grid or as emergency power-supply with grid failure.